Denver metro & nationwide · 24/7 emergency service (720) 603-8665
Request a Quote

Electrical Services

Commercial Battery Energy Storage in Colorado

Battery energy storage systems for commercial and industrial facilities: demand charge reduction, backup power and solar pairing, installed to code and through utility interconnection.

A battery energy storage system (BESS) is an electrical project with a fire code attached. The batteries and the enclosure come from the manufacturer; the service, protection, interconnection, controls and life-safety coordination decide whether it gets permitted, energised and earns its cost. That's the part we do.

Why facilities add battery storage

  • Demand charge reduction: discharging at peak so the facility never sets a high monthly demand reading
  • Backup power: riding through outages for critical loads, alone or alongside a generator
  • Solar pairing: storing on-site solar for use at peak or after dark
  • Time-of-use savings where the rate structure supports it
  • EV charging support: buffering fast chargers so they don't drive demand charges or a service upgrade

What we handle

  • Service, switchgear and distribution modifications to accept the system
  • BESS and inverter installation, wiring, grounding and protection
  • Utility interconnection applications, protection settings and witness testing
  • Automatic transfer and islanding for backup operation
  • Metering, monitoring and controls integration
  • Coordination with the fire marshal on siting, separation and detection
  • Commissioning and documentation

Codes that shape the project

The electrical installation falls under NEC Article 706, which covers wiring methods, disconnects, overcurrent protection, grounding and labelling for energy storage systems. NFPA 855 and the fire code govern where the system can go, how far it sits from doors and windows, how much capacity fits in a room, and what detection and suppression it needs. The equipment itself has to be listed, typically to UL 9540. Getting siting right at design avoids the expensive surprise: a plan review that moves the batteries after the electrical design is done.

The numbers have to work

Storage rarely pays for itself on backup value alone. Savings come mostly from demand charges and depend on your load profile and rate schedule, so we model the system against your actual utility bills and interval data before recommending a size. If the numbers don't work, we'll tell you.

Power quality comes with it

Inverters change a facility's harmonic profile. On sites already carrying drives, UPS or EV chargers, a large storage system can push a service toward IEEE 519 limits. We check that at design. See power quality analysis.

For solar plus storage, see commercial solar and storage. For emergency lighting batteries, see emergency lighting inverters and batteries.

Common questions

Does battery storage pay for itself?

It depends on your demand charges and load profile. Most of the savings come from cutting peak demand. We model the system against your real bills and interval data before recommending a size, and we'll tell you if it doesn't pencil out.

What codes apply to a commercial battery system?

NEC Article 706 covers the electrical installation. NFPA 855 and the fire code cover siting, separation, capacity limits and fire protection. The equipment is typically listed to UL 9540.

Can a battery system replace our generator?

For short outages and some critical loads, sometimes. For long outages, batteries usually work alongside a generator rather than replacing it. We size it to how long you actually need to run.

Do you handle the Xcel Energy interconnection?

Yes. We manage the interconnection application, protection requirements, metering and witness testing, and start early, because interconnection is usually the schedule risk.

Can storage help with EV fast chargers?

Yes. A battery can supply the charger's peak draw so it doesn't set a demand charge or force a bigger utility service.

Ready to talk about your project?

Tell us what you need and we will give you a straight answer on scope, schedule and cost. No obligation, and no pressure if it turns out we are not the right fit.